8-26 – Tail Rotor Balance
Chapter 8
Revision 3.00, April 2020
8.8.
–Analyzer Chart Forms
Just as in the case with polar balance charts, there are two types of analyzer chart “forms”
used with the analyzer. The chart forms are also categorized as either “Regular” or
“Irregular”. The selection of setup type is made within the chart form itself by using either
the [
] or [
] keys to toggle between “Regular” and “Irregular” in the “Chart Type” field,
then pressing the [
] key to move to the next field. The remaining fields in the screen will
automatically change if necessary. The paragraphs below describe these forms in detail.
8.8.1.
– Regular Chart Forms
A “Regular” chart is one that has all weight positions spaced equally around the chart, all
adjustments are of the same type, and all adjustments carry the same ICF. The next paragraph
details the process for defining a tail rotor “Regular” chart setup.
- Regular Tail Rotor Chart Setup
The tail rotor balance chart shown to the right depicts
six adjustment points. Each adjustment point has
been circled to ease identification and differentiate
them from the clock hours. The move line for each
adjustment point has been indicated with an arrow,
and the ICF is labeled at the bottom of the chart as
being 12 grams per 1.0 IPS. This chart meets all
criteria to place it in the “Regular” chart type
category, all weight positions have the same ICF and
type of adjustment, and all move lines are equally
spaced around the chart. Using this chart, follow the
examples below to properly define a “Regular” tail
rotor chart setup in the analyzer.
ICF = 12.0 Grams / 1.0 IPS