background image

KANE958

 

Stock No: MAN00231 Rev: 1.00322

 

 

 

 

 

MARCH 2022

 

©

 Kane International Ltd

 

Flue Gas Analyser with direct O2

 

Measurement and CO sensor protection

 

KANE    

LINK

 

Содержание KANE958

Страница 1: ...KANE958 Stock No MAN00231 Rev 1 00322 MARCH 2022 Kane International Ltd Flue Gas Analyser with direct O2 Measurement and CO sensor protection KANE LINK...

Страница 2: ...DATE 9 CHARGING NIMH BATTERIES 9 BATTERY DISPOSAL 9 GENERAL SAFETY 10 FIRST TIME USE 11 GENERAL OPERATING PRINCIPLE 11 15 QUICK START 11 USER INTERFACE 11 STATUS 12 STATUS BAR 12 STATUS BAR LAYOUT 13...

Страница 3: ...REPORTS 20 REPORT MENU OPTIONS 21 PRESSURE TEMPERATURE TESTING 21 TEMPERATURE PRESSURE DISPLAY 22 VIEWING SENDING PRINTING 22 PRESSURE MEASUREMENT GOOD PRACTICE 22 LARGE BORE TUBING ISSUES 23 PRINTIN...

Страница 4: ...ith a flue probe with integral temperature sensor Your KANE958 has a low flow detector system to switch off the analyser pump if it detects water entering from an over filled water trap Your KANE958 h...

Страница 5: ...ANALYSER FEATURES AND KEYPAD KANE958 MANUAL 5...

Страница 6: ...n choice when wireless irda fitted NAVIGATE UP Short press to scroll up ENTER KEY Use to select current option also selects torch in some dial positions NAVIGATE DOWN Short press to scroll down DATA H...

Страница 7: ...er KANE958 MANUAL 7 Flue Probe Temperature Plug Into T1 Narrow ve pin must be on right side Red connector plugs into Flue Gas Inlet Flue probe hose Battery charger Inlet T2 Flue gas inlet Watertrap dr...

Страница 8: ...8 KANE958 MANUAL Thermocouple Stainless steel shaft Depth stop cone Gas path Thermocouple wire Water trap drain with red plug Magnets x2 Gas exhaust P10...

Страница 9: ...ring correct battery polarity Replace battery cover protective rubber cover TIME AND DATE After changing batteries reset your analyser time date CHARGING NiMH BATTERIES Your KANE958 uses a standard Mi...

Страница 10: ...es to change the output of all sensors present NOTE This is different from a calibration where your analyser is exposed to known gas mixtures but allowed to settle to a steady figure with readings adj...

Страница 11: ...L OPERATING PRINCIPLE Using your KANE958 is simple with the rotary dial and user interface Most tests can be made with little user activity Your analyser status bar offers options based on tasks you a...

Страница 12: ...your settings Navigate through status bar options via buttons when status bar is on display 12 KANE958 MANUAL Status bar Current fuel selection use status bar menu to change fuel selection Current am...

Страница 13: ...ON DUE WARNING MESSAGE AIR PURGE SNOOZE TIMER LOW BATTERY WARNING MESSAGE Displays current time Display alternates between hold symbol Time stamp of held data Display alternates between calibration du...

Страница 14: ...k and simple status information STAUS BAR ICON LEVEL ICON LIST PUMP LOGGED DATA SENDING DATA BATTERY Pump status On or Off Analyser has logged stored data Data being sent to App or Printer Battery Sta...

Страница 15: ...e up or down items will move up or down the screen returning to the beginning Note To exit menu turn your analyser rotary dial to any position note any unsaved changes will be lost Date Displays selec...

Страница 16: ...entage of NO2 NOx equations are NOx reference to NO NOx sum equation NO NO2 NOx reference to NO2 LOGS LOGS View current memory usage stored logs AIRFLOW AIRFLOW Change airflow scale and adjust pitot f...

Страница 17: ...o the flue so no air can back flush into the probe SAFETY WARNING Ensure your flue probe handle does not get hot Do not exceed analyser operating specifications In particular Do not exceed flue probe...

Страница 18: ...e AUX SCREEN EDITING THE AUX SCREEN You can customise lines 1 to 5 of your analyser AUX screen To edit a line press until EDIT appears on the status bar Press and hold to select EDIT Cursor flashes an...

Страница 19: ...l to MENU then select LOGS to display MENU OTIONS KANE958 MANUAL 19 CO reading CO normalised Excess air reading Loss reading Status bar No of stored Combustion logs No of stored Temperature logs Total...

Страница 20: ...ort type the first stored log is displayed List of available LOGS To navigate and select use 20 KANE958 MANUAL View stored Combustion Reports View stored Auxiliary Reports View stored Pressure Tempera...

Страница 21: ...er pressure transducer is rated at 160 mbar with a maximum over range of 400 mbar Rotate dial to Prs Temp and use the black connectors manometer hose to connect to P1 for single pressure or P1 P2 for...

Страница 22: ...ENT GOOD PRACTICE WARNING Before using your KANE958 to measure an appliance gas air ratio valve read appliance manufacturer instructions thoroughly If in doubt contact appliance manufacturer After adj...

Страница 23: ...ORE TUBING ISSUES If using large bore tubing when performing pressure tests Push orange tube over rim of spigot to ensure a gas tight seal Failure to do so may not produce a gas tight seal 23 KANE958...

Страница 24: ...er or wirelessly to KANE APP You can stop printing by pressing button again KANE INFRARED PRINTER To use your printer switch on and place the printer infrared receiver in line with the emitter on top...

Страница 25: ...PRINTOUTS KANE958 MANUAL 25 Auxiliary Combustion Pressure Temp...

Страница 26: ...ng buttons WPCP2 WIRELESS PIPE CLAMP To add select it then enter its serial number using buttons Enter its serial number using buttons Each clamp serial number must be 10 digits long If longer use the...

Страница 27: ...Sulphur Dioxide optional 0 5000ppm 1ppm 5ppm 100ppm 5 100ppm Pressure Measurement Pressure Differential 160mbar 0 1mbar 0 5 FSD Calculations CO CO2 Ratio 0 0 9999 0 0001 5 of reading Efficiency Net or...

Страница 28: ...D 28 KANE958 MANUAL Operating Conditions Temperatures 0 45 C Humidity 15 t 90 RH non condensing Power Supply Rechargeable batteries USB Charging Physical Characteristics Weight Approx 0 625g Dimension...

Страница 29: ...SAFETY EN61010 1 2010 ROSH UK EU IEC62321 2 2013 IEC62321 1 2013 IEC62321 3 1 2013 IEC62321 5 2013 IEC62321 4 2013 IEC62321 7 2 2017 IEC62321 7 1 2015 IEC62321 6 2015 Signed for on behalf of Kane Int...

Страница 30: ...y being left in a vehicle overnight suffer when taken into a warm room the next morning Condensation may form affecting analyser performance Analyser electrochemical sensors are affected by condensati...

Страница 31: ...ll analysers pressure meters should be recertified annually Extend your KANE analyser pressure meter s no quibble warranty up to 10 years by returning your analyser pressure meter via your KAM dashboa...

Страница 32: ...ificates when required for compliance Report Stolen Reporting your analyser stolen ensures our Stolen Analyser Register is up dated helps prevent industry colleagues unknowingly buying stolen goods Re...

Страница 33: ...Your support our way 33 KANE958 MANUAL...

Страница 34: ...Service Recertification Register your analyser on www kane co uk Book pay to Service Recertify via your KAM dashboard Select FREEPOST for tracked Carriage UK mainland only Your analyser will be despa...

Страница 35: ...THIS PRODUCT CONFIRMS WITH THE FOLLOWING PLEASE RECYCLE PACKAGING MADE IN THE UK 35 KANE958 MANUAL...

Страница 36: ...ter on our website www kane co uk Scan the QR code to go directly to Register your product online Kane International Ltd Kane House 11 Bessemer Road Welwyn Garden City Hertfordshire AL7 1GF UK email s...

Отзывы: