![ACES SYSTEMS Cobra II Скачать руководство пользователя страница 119](http://html.mh-extra.com/html/aces-systems/cobra-ii/cobra-ii_user-manual_3046612119.webp)
Gen II
User Manual
7-27 – Main Rotor Track & Balance
Chapter 7
Revision 3.00, Apr 2020
When you have completed reviewing the data, and all conditions data has been collected press
[OK] to continue to the solution screens.
7.2.7.
– Solution Screens
The number and type of solutions presented will depend upon the data gathered and the targets
that were set for each of the measurement types in the “Conditions Setup” screen when the setup
was defined. Solutions will be an average adjustment to correct for all flight conditions
collected. If different type of adjustments are in the setup, then an average adjustment will be
presented for each. Choose the solution for the current run, highlight it with the cursor and press
[OK] to view the actual solution. Typically, starting with the first suggestion and applying
corrections until this exceedance is under the defined target before proceeding to the next
solution will be the best course of action.
The analyzer will present all of the solutions that are possible from the data gathered for the
current run. This means that it is possible for the analyzer to give two adjustments that would
adversely affect the other. The user will ultimately be responsible for determining which
adjustments to make and which to discard.
For instance, the analyzer can recommend solutions for both the pitch change links and the main
rotor blade trim tabs for the same run. If you were to make both of these adjustments, chances
are, this would over-correct causing counter-adjustments on the next run. Most likely in this
case, and depending on the amount of PCL adjustment, the trim tab adjustment would be skipped
and only the pitch change link adjustment would be made.
As stated earlier, the solutions presented by the analyzer are based on the charts defined in the
setup and the measurements acquired for the current run. These influences will be updated each