MC97F6108A User’s manual
11. PPG (Programmable Pulse Generator)
123
ATPMINLR (Auto Period Mode Min Period Low Register) : 2F06H
7
6
5
4
3
2
1
0
ATPMINLR7 ATPMINLR6 ATPMINLR5 ATPMINLR4 ATPMINLR3 ATPMINLR2 ATPMINLR1 ATPMINLR0
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
Initial value: 00H
ATPMINLR[7:0]
Auto Period Mode Min Period Low Register
ATPMINHR (Auto Period Mode Min Period High Register) : 2F07H
7
6
5
4
3
2
1
0
ATPMINHR7 ATPMINHR6 ATPMINHR5 ATPMINHR4 ATPMINHR3 ATPMINHR2 ATPMINHR1 ATPMINHR0
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
Initial value: 00H
ATPMINHR[7:0]
Auto Period Mode Min Period High Register
OFFCR (PPG Off-Time Control Register) : B9H
7
6
5
4
3
2
1
0
OFMAX
OFMIN
0
-
-
-
-
-
R/W
R/W
R/W
-
-
-
-
-
Initial value: 00H
OFMAX
Enable or Disable PPG max off-time.
0
Disable
1
Enable
OFMIN
Enable or Disable PPG min off time
0
Disable
1
Enable
OFFMAXLR (PPG Off Time Max Period Low Register) : 2F0CH
7
6
5
4
3
2
1
0
OFFMAXLR7
OFFMAXLR6
OFFMAXLR5
OFFMAXLR4
OFFMAXLR3
OFFMAXLR2
OFFMAXLR1
OFFMAXLR0
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
Initial value: 00H
OFFMAXLR[7:0]
PPG Off Time Max Period Low Register
OFFMAXHR (PPG Off Time Max Period High Register) : 2F0DH
7
6
5
4
3
2
1
0
OFFMAXHR7 OFFMAXHR6 OFFMAXHR5 OFFMAXHR4 OFFMAXHR3 OFFMAXHR2 OFFMAXHR1 OFFMAXHR0
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
Initial value: 00H
OFFMAXHR[7:0]
PPG Off Time Max Period High Register
OFFMINLR (PPG Off Time Min Period Low Register) : 2F0EH
7
6
5
4
3
2
1
0
OFFMINLR7 OFFMINLR6 OFFMINLR5 OFFMINLR4 OFFMINLR3 OFFMINLR2 OFFMINLR1 OFFMINLR0
R / W
R / W
R / W
R / W
R / W
R / W
R / W
R / W
Initial value: 00H
OFFMINLR[7:0]
PPG Off Time Min Period Low Register