20
1
P-TEST button
The P-TEST button performs a quick performance test.
The quick performance test automatically checks the performance of the
balance by loading and unloading the internal weight. Refer to “
2
APP button
The APP button displays the application setting screen and saves the
settings related to weighing.
Main items: Application selection (Normal weighing, Counting mode,
Percent mode, Minimum weight alert function, Unit of measure, Minimum
display digit, Statistical calculation function, Decimal separator, Warning
display, etc.) Refer to “
3
Left IR sensor function
change button
Displays the options for changing the IR sensor operation settings.
You can configure the settings individually for the left and right IR
sensors. At the factory setting, they open/close the breeze break door.
4
Stabilization indicator
Displayed when the weighing value of the balance is stable.
5
Left IR sensor
A touchless sensor. When you bring your hand closer, it reacts and the
assigned breeze break door opens/closes (at the factory setting). Refer
to “
6
Weighing display
Displays the weighing value of the balance.
7
ON:OFF key
Turns the screen display on and off. The ON:OFF key is active during
any operation.
When the screen display is turned off, the standby screen appears.
When the screen display is turned on, the weighing screen appears.
8
HOME key
Displays the weighing screen. The HOME key is active during any
operation.
9
PRINT button
Outputs data to the device connected to the balance.
Refer to “
16. Connection with Peripheral Devices
10
CAL button
The CAL button displays the [Sensitivity adjustment/calibration test]
screen. Select and execute the sensitivity adjustment/calibration test with
the internal or external weight. Refer to “
11
Communication device
setting button
Displays the [
] screen.
Configure the settings of or remove the connected communication
device.
12
Right IR sensor function
change button
Displays the options for changing the IR sensor operation settings.
You can configure the settings individually for the left and right IR
sensors. At the factory setting, they open/close the breeze break door.
13
Capacity, readability
Displays the capacity and readability of the balance.
14
Right IR sensor
A touchless sensor. When you bring your hand closer, it reacts and the
assigned breeze break door opens/closes (at the factory setting). Refer
to “
15
Date/time display
Displays the current date and time.
16
Warning display
Refer to the next page.
17
Unit display
Displays the set unit.
Содержание BA-T Series
Страница 1: ...BA 6TE BA 6DTE BA 225TE BA 225DTE BA 125DTE 1WMPD4004315C...
Страница 5: ...5 11 Calibration test check 101 12 Filter Settings 135 13 System settings 137...
Страница 107: ...107 Output example for daily check output results Daily check output results Daily check PDF results...
Страница 117: ...117 Output example for periodic check output results Periodic check output results...
Страница 118: ...118 Periodic check results PDF...
Страница 129: ...129 AND MEET analysis graph example...
Страница 215: ...215 Unit mm Display unit 138 182 73 Ionizer 162 68 129...
Страница 219: ......