Table of Contents
ZEISS
5 Commissioning and First Operating Steps....................................... 68
Prerequisites for Commissioning and Operation .................................................. 69
Energizing the Microscope .................................................................... 69
Starting the Microscope ........................................................................ 71
Keyboard Shortcuts............................................................................... 72
Preparing the Specimen Holder ............................................................. 74
Loading the Specimen Chamber............................................................ 76
Locating the Specimen .......................................................................... 79
Switching on the Gun ........................................................................... 80
Switching on the EHT............................................................................ 80
Acquiring an Image............................................................................... 81
Optimizing the Image............................................................................ 83
Selecting the Gun Mode........................................................................ 85
Setting the Probe Current...................................................................... 86
Continuously Modifying the Probe Current (License: OPTIPROBE) .......... 86
Measuring the Probe Current ................................................................ 87
Changing the Extractor Voltage ............................................................ 88
Working with Different Aperture Configurations and Beam Modes .................... 89
5.6.1
Determining the Installed Aperture Configuration | Gemini 2 Column.... 89
Selecting the Aperture .......................................................................... 90
Selecting the Column Mode .................................................................. 90
Setting up the InLens SE Detector ......................................................... 92
Setting up the SE Detector .................................................................... 92
Setting up the VPSE Detector ................................................................ 93
Setting up the C2D Detector ................................................................. 94
Setting up the AsB Detector .................................................................. 95
Setting up the AsB4 Detector ................................................................ 96
Setting up the aBSD/aBSD-LH/VP-BSD Detector..................................... 98
Setting up the YAG BSD Detector.......................................................... 99
5.7.10 Setting up the EsB Detector................................................................... 100
5.7.11 Setting up the SCD Detector ................................................................. 101
5.7.12 Setting up the aSTEM Detector ............................................................. 101
5.7.13 Setting up the CL Detector .................................................................... 103
Working with Variable Pressure...........................................................................103
5.8.1
Changing to Standard VP Mode ............................................................ 104
Using Nano VP or XVP Mode ................................................................ 105
Returning to HV Mode .......................................................................... 111
Finishing the Work Session.................................................................... 112
De-energizing the Microscope............................................................... 112