Making Preparations for Measurements
3-3
IM 701310-01E
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
App
Index
3.2 Installing the Instrument
Installation Conditions
Install the instrument in a place that meets the following conditions.
Flat, Even Surface
Install the instrument with the correct orientation on a stable, horizontal surface. The
recording quality of the printer may be hindered when the instrument is placed in an
unstable or inclined place.
Well-Ventilated Location
Inlet holes are located on the top and bottom of the instrument. There are also exhaust
holes on the right side. To prevent internal overheating, allow for enough space around
the instrument (see the figure below) and do not block the inlet and exhaust holes.
CAUTION
If the inlets on the left and bottom side of the instrument, and exhaust holes on the
right side are blocked, the temperature of the instrument will rise, and can result in
damage.
ESC
RESET
SET
M
k
m
u
n
p
D
E
F
X
A
B
C
7
8
9
4
5
6
1
2
3
0
BS
CLEAR
EXP
MENU
FILE UT
ILITY
FILE
SYSTEM
SHIFT
SETUP
HELP
HISTOR
Y CLEA
R
HISTOR
Y
ACQ CO
UNT/ACT
ION
ZOOM
DISP 1
DISP 2
ZOOM
1
ZOOM
MAG
ACQUIR
E/HORIZ
ONTAL
ACQ
START/S
TOP
SAMPLIN
G/
LENGTH
POSITIO
N/
DELAY
T/DIV
TRIGGER
EDGE/
STATE
ENHANC
ED
WIDTH
EVENT
INTERVA
L
SOURC
E
INTEN
SITY
ACCUM
FORM
ACCUM
ANALYS
IS/
XY
WINDOW
1
WINDOW
2
CURSO
R
TELECO
M TEST
PARAM
VERTICA
L
CH 1
M 1
CH 2
CH 3
CH 4
M 2
M 3
M 4
POSITIO
N
TRIG'D
TRIG MO
DE/
HOLD OF
F
PUSH
FINE
PUSH
FINE
SCALE
SNAP CLE
AR
SNAP
POW
ER
COM
P
CH
2
3
4
1 M
/20 pF
150Vr
ms C
ATI 5
0
5 Vrm
s,10 V
pk
LEVEL/
COUPLING
DL924
0L
10GS/s
1.5GHz
DIGITA
L OSCIL
LOSCO
PE
CH
CH
1
CH
DISPLAY
CLEAR
10 cm
or more
10 cm
or more
10 cm or more
5 cm
or more
ESC
RESET
SET
M
k
m
u
n
p
D
E
F
X
A
B
C
7
8
9
4
5
6
1
2
3
0
BS
CLEAR
EXP
MENU
PRINT
FILE UTILITY
FILE
SYSTEM
SHIFT
SETUP
HELP
HISTORY CLEAR
HISTORY
ACQ COUNT/ACTION
ZOOM
DISP 1
DISP 2
ZOOM 1
ZOOM 2
MAG
ACQUIRE/HORIZONTAL
ACQ
START/STOP
SAMPLING/
LENGTH
POSITION/
DELAY
T/DIV
TRIGGER
EDGE/
STATE
ENHANCED
WIDTH
EVENT
INTERVAL
SOURCE
DISPLAY
INTENSITY
ACCUM CLEAR
FORM
ACCUM
ANALYSIS/
XY
WINDOW 1
WINDOW 2
MEASURE
CURSOR
TELECOM TEST
PARAM
VERTICAL
CH 1
M 1
CH 2
CH 3
CH 4
M 2
M 3
M 4
POSITION
TRIG'D
TRIG MODE/
HOLD OFF
PUSH
FINE
PUSH
FINE
SCALE
SNAP CLEAR
SNAP
POWER
COMP
CH 1
CH 2
CH 3
CH 4
1 M /20 pF 150 Vrms CAT I 50
5 Vrms,10 Vpk
LEVEL/
COUPLING
DL9240L 10GS/s 1.5GHz
DIGITAL OSCILLOSCOPE
Including the spaces shown in the drawing above, allow for plenty of space to connect
the cables and to open and close the cover of the built-in printer.