17-3
IM DL850E-01EN
• Wiring unit Σ measurement functions
The following 24 measurement functions are available.
UΣ (average voltage): UrmsΣ (rms value),* UmnΣ (rectified mean value calibrated to the rms value),* UdcΣ
(simple average), UacΣ (AC component)
IΣ (average current): IrmsΣ (rms value),* ImnΣ (rectified mean value calibrated to the rms value),* IdcΣ (simple
average), IacΣ (AC component)
PΣ (total active power), SΣ (total apparent power), QΣ (total reactive power), λΣ (average power factor), φΣ
(average phase difference)
WPΣ (total integrated power), WP+Σ (total positive integrated power), WP-Σ (total negative integrated power),
qΣ (total integrated ampere-hour), q+Σ (positive total integrated ampere-hour), q-Σ (negative total integrated
ampere-hour),
WSΣ (total apparent energy), WQΣ (total reactive energy), ZΣ (average impedance), RSΣ (average series
resistance), XSΣ (average series reactance), RPΣ (average parallel resistance), XPΣ (average parallel
reactance)
* You can select either the rms value or the rectified mean value calibrated to the rms value (but not both). In
either case, the value is displayed as rms.
• Delta math measurement functions
For details on line voltages and R, S, and T points, see the
3P3W→3V3A
The following 8 measurement functions are available.
Urs (R-S line voltage): Urms3 (rms value),* Umn3 (rectified mean value calibrated to the rms value),* Udc3
(simple average), Uac3 (AC component)
It (phase current): Irms3 (rms value),* Imn3 (rectified mean value calibrated to the rms value),* Idc3 (simple
average), Iac3 (AC component)
3V3A→3P4W
The following 13 measurement functions are available.
Ur (R-N voltage): Urms1 (rms value),* Umn1 (rectified mean value calibrated to the rms value),* Udc1 (simple
average), Uac1 (AC component)
Us (S-N voltage): Urms2 (rms value),* Umn2 (rectified mean value calibrated to the rms value),* Udc2 (simple
average), Uac2 (AC component)
Ut (T-N line voltage): Urms3 (rms value),* Umn3 (rectified mean value calibrated to the rms value),* Udc3
(simple average), Uac3 (AC component)
In (neutral line current)
3P4W→3V3A
The following 13 measurement functions are available.
Urs (R-S voltage): Urms1 (rms value),* Umn1 (rectified mean value calibrated to the rms value),* Udc1 (simple
average), Uac1 (AC component)
Ust (S-T voltage): Urms2 (rms value),* Umn2 (rectified mean value calibrated to the rms value),* Udc2 (simple
average), Uac2 (AC component)
Utr (T-R line voltage): Urms3 (rms value),* Umn3 (rectified mean value calibrated to the rms value),* Udc3
(simple average), Uac3 (AC component)
In (neutral line current)
* You can select either the rms value or the rectified mean value calibrated to the rms value (but not both). In
either case, the value is displayed as rms.
• Other measurement functions
The following 3 measurement functions are available.
η (efficiency): Motor efficiency, power efficiency
Uubf (three-phase voltage unbalance factor)
Iubf (three-phase current unbalance factor)
17 Power Math