One-Shot Output Settings (One shot out Setup)
A single specified data frame or remote frame is output at the specified time.
Message Format
Select the message format.
STD: Standard format
XTD: Extended format
ID (Hex)
Set the message ID of the output data frame.
Standard format (11 bits): 0x000 to 0x7ff
Extended format (29 bits): 0x00000000 to 0x1fffffff
Frame
Select the frame type.
Remote: Remote frame
Data: Data frame
DLC
Set the byte size of the data area of the data frame.
Selectable range: 0 to 15
Data (Hex)
Configure this setting when the frame type (Frame) is set to Data.
In hexadecimal notation, specify the data frame value to output.
Output
Output the data.
You cannot output the data when in the Port Setup menu, Listen Only is set to ON.
Configuring the Scales of All Sub Channels (All SubChannel Scale)
Configure the scales of all sub channels.
All SubChannel Auto: The upper and lower display range limits are set automatically.
All SubChannel Default: To the greatest extent possible within the settable range, the maximum and minimum
values are used to set the upper and lower limits of all sub channels.
CAN Frame Formats
Data Frames
• Standard format
1
11
1 1 1 4
15
8N (0 ≤ N ≤ 8)
1 1 1
ID 28-18
Arbitration Field
Control Field Data Field
CRC Field ACK
Data Frame
DLC
3-0
CRC
Sequence
Data
7
EOF
Recessive
Dominant
SOF
R
TR IDE RB0
ACK Boundary
ACK slot
CRC Boundary
• Extended format
1
11
1 1 1 4
8N (0 ≤ N ≤ 8)
15
1 1 1 7
1 1
18
ID 28-18
ACK
Data Frame
ID 17-0
DLC
3-0
CRC
Sequence
EOF
Data
Arbitration Field
Control Field Data Field
CRC Field
SOF
SRR IDE
ACK Boundary
ACK Slot
CRC Boundary
R
TR
RB0
RB1
2 Vertical Axis