17-5
IM DL850E-01EN
• Single-Phase Two-wire (1P2W)
Two channels that receive one pair of voltage and current signals can be wired.
LOAD
U
I
H
H
SOURCE
L
L
H
L
CH1
H
L
CH2
LOAD
SOURCE
Clamp sensor
• Single-Phase Three-Wire (1P3W)
Four channels that receive two pairs of voltage and current signals can be wired.
SOURCE
LOAD
LOAD
N
H
H
L
H
L
L
H
L
I2
I1
U1
U2
H
N
L
CH1
U1
I1
H
L
CH2
H
L
CH3
U2
I2
H
L
CH4
SOURCE
Clamp sensor
Clamp sensor