IBERT Virtex-6 FPGA GTX Transceiver Toolbar and Menu Options
IBERT Console Options
The IBERT Console Options dialog allows you to select which columns and rows to
display in the IBERT Console. The left-hand panel selects the MGTs by location. Use the
Check All
and
Uncheck All
buttons to select all or none of the MGTs.
The right-hand panel selects which rows are displayed in the MGT/BERT settings. Use the
Check All
and
Uncheck All
buttons to select all or none of the rows. The
Default
button
sets up the Console to display the basic set of rows needed to determine the health of the
channels. The Default rows are Tile Location, TX PLL Status, RX PLL Status, Loopback
Mode, Channel Reset, TX Error Inject, Rx Sampling Point, TX Data Pattern, RX Data
pattern, Rx Bit Error Ratio, Rx Received Bit Count, Rx Bit Error Count, BERT Reset,
TXUSRCLK2 Freq, and RXUSRCLK2 Freq.
Import/Export Dialog
In the Import/Export dialog box, you can save and recall settings from a specific MGT, or
apply the setting of one MGT to others in the design. To import or export settings, use
IBERT_V6GTX
>
Import/Export Wizard
or click the
Import/Export Wizard
button in the
toolbar.
The first screen of the wizard chooses the source of the MGT settings - either
MGT
or
File
.
If
MGT
is selected, choose among the available MGTs in the combo box. For
File
, click
Browse
and navigate to the settings file. Click
Next
to go to the next screen.
The second screen is the destination screen. Any combination of the MGTs in the IBERT
design and a file are available. If
File
is enabled, click
Browse
to specify the file destination.
The third screen is the confirmation screen, summarizing the source and destination(s) for
the settings. Click
Apply
to execute the import or export. This operation cannot be undone.
Reset All
To reset all the channels in the IBERT core, use
IBERT_V6GTX
>
Reset All
or click the
Reset All
button in the toolbar.
JTAG Scan Rate and Scan Now
The
JTAG Scan Rate
toolbar and
IBERT_V6GTX
>
JTAG Scan Rate
menu options are
used to select how frequently the ChipScope Pro Analyzer tool queries the IBERT core for
status information. The default is 1s between queries, but it can be set to 250 ms, 500 ms, 1s,
2s, 5s, or Manual Scan. When Manual Scan is selected, use
IBERT_V6GTX
>
Scan Now
or
the
Scan Now
(or
S!
) toolbar button to query the IBERT core.
IBERT Console Window for Virtex-6 FPGA GTH Transceivers
To open the console for a ChipScope Pro IBERT core for Virtex-6 HXT families, select
Window > New Unit Windows
and the desired core. A dialog box displays for that core,
and you can select the
IBERT V6 GTH Console
. You cannot close windows from this
dialog box.
You can achieve the same operation by double-clicking on the
IBERT V6 GTH Console
leaf node in the project tree, or by right-clicking on the
IBERT V6 GTH Console
leaf node
and selecting
Open IBERT V6 GTH Console
.