PC Setup 3-75
Fig. 3.166 Advanced Graphics Center
Fig. 3.167 AGC Setup Window
2.
Select your printer model and make necessary adjustments to paper trays, paper
sizes, interface port, and resolution settings according to your printer setup.
Then, click either Linearize or More X-ACT.
When calibrating for plate, you
must
select the manual feed tray by selecting the
Manual Feed Tray option in the AGC Setup Window.
Linearize
To begin linearizing your printer, you must first print a calibration page to measure
the printer’s current performance as a basis for the calibration.
Always
print the calibration page using the same media and toner or press ink as used
for the final copy. When possible, calibrate from the final output. For example when
calibrating for plates, take the plate to press and print. Then, measure the output from
the press.
You
must
use a densitometer capable of measuring dot area for the linearization
process.
1.
Make sure the resolution which you will use to print the final output is selected
in the AGC Setup window (fig. 3.167) under Resolution Supported.