Manual 85580V2
5009 Installation/Hardware
Woodward
13
Figure 2-9. SIO Module Block Diagram
Cabinet (optional)
If a cabinet is included with the system, a standard floor mount, front access
cabinet is provided. Input Power and field cable access are available through the
bottom of the cabinet. When a cabinet is included with a system, the control is
shipped fully assembled within the cabinet. The cabinet’s weight is approximately
600 lbs (272.4 kg) including control. The provided cabinet meets NEMA 12
ratings. Refer to Chapter 6 of this Volume for all Cabinet material specifications.
Refer to Figures 4-18a and 4-18b for control cabinet diagrams. This panel is a
UL Listed industrial control panel.
OpView™ Operator Interface (optional)
The OpView™ Operator Interface is a computer-based work-station that
functions as a touch screen annunciator and operator control panel for
Woodward digital control systems. This work-station allows an operator to
remotely view operating inputs, vary control setpoints, and issue Run mode
commands. The OpView is comprised of an industrialized (optional Class I
Division 2) touch screen hardware package and a Woodward developed
software program. This standard program allows the OpView to automatically
select the correct interface screens based on 5009 control’s configuration. No
field configuration is necessary. Refer to Table 3-1 and Figure 3-1 for
identification and Volume #4 of this manual for device specific details.
Summary of Contents for MicroNet TMR 5009
Page 8: ...5009 Installation Hardware Manual 85580V2 vi Woodward...
Page 23: ...Manual 85580V2 5009 Installation Hardware Woodward 15 Figure 3 1 Hardware Identification...
Page 33: ...Manual 85580V2 5009 Installation Hardware Woodward 25 Figure 3 7 DIN Rail ATM Outline Drawing...
Page 35: ...Manual 85580V2 5009 Installation Hardware Woodward 27 Figure 3 9 DTM Outline Drawing...
Page 36: ...5009 Installation Hardware Manual 85580V2 28 Woodward Figure 3 10 DTM Mounting Configuration...
Page 68: ...5009 Installation Hardware Manual 85580V2 60 Woodward Figure 4 19 System Cable Layout Diagram...
Page 69: ...Manual 85580V2 5009 Installation Hardware Woodward 61 Figure 4 20 Power Supply Wiring Diagram...
Page 70: ...5009 Installation Hardware Manual 85580V2 62 Woodward Figure 4 21 ATM 1 Wiring Diagram...
Page 71: ...Manual 85580V2 5009 Installation Hardware Woodward 63 Figure 4 22 ATM 2 Wiring Diagram...
Page 72: ...5009 Installation Hardware Manual 85580V2 64 Woodward Figure 4 23 DTM 1 Wiring Diagram...
Page 73: ...Manual 85580V2 5009 Installation Hardware Woodward 65 Figure 4 24 DTM 2 Wiring Diagram...
Page 74: ...5009 Installation Hardware Manual 85580V2 66 Woodward Figure 4 25 DTM 3 Wiring Diagram...
Page 75: ...Manual 85580V2 5009 Installation Hardware Woodward 67 Figure 4 26 DTM 4 Wiring Diagram...
Page 89: ...Manual 85580V2 5009 Installation Hardware Woodward 81 Table 5 3 Discrete In Cable Connections...
Page 90: ...5009 Installation Hardware Manual 85580V2 82 Woodward Table 5 4 Relay Cable Connections...
Page 91: ...Manual 85580V2 5009 Installation Hardware Woodward 83 Table 5 4 Relay Cable Connections cont...
Page 92: ...5009 Installation Hardware Manual 85580V2 84 Woodward Table 5 5 Analog Combo Module...
Page 103: ...Manual 85580V2 5009 Installation Hardware Woodward 95 Figure 8 2 Operator Control Panel...
Page 108: ...5009 Installation Hardware Manual 85580V2 100 Woodward Figure 8 6 Real Power Sensor...
Page 115: ......
Page 116: ...Declarations...