Request timed out
:
Request timed out
Reply from 200.243.232.178: bytes=32 time=2ms TTL=255
Reply from 200.243.232.178: bytes=32 time=2ms TTL=255
Ping statistics for 200.243.232.178:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milliseconds:
Minimum = 1ms, Maximum = 2ms, Average = 1ms
If the above “ping” reply does not appear, press 'F3' and 'Enter' keys. Normally “Request timed
out” messages appear 7 times before reply ing properly.
Once the above “ping” reply appears press <Ctrl>+<C> keys to make it stop.
When the “ping” reply stops, data loss may range from 0% to 99%. This is normal. If the statistic
shows ‘100% loss’, check the following criterions: (a) network line and connection status are
stable; (b) IP address assigned to WebEye is available; (c) PC and WebEye have the same local
network IP address. Same local IP address of C grade network means that first 3 sets of numbers
are the same but the fourth set is different. For example 192.168.1.2 and 192.168.1.3 are in the
same local network. (If there is a ‘Network Mask’ on the network, this can be an exception. For
detailed information on IP, refer to appendix 4)