7) Video Configuration
This page is to configure every channel with various conditions.
(1) Video Channel Selection
WebEye El04
User chooses video channels to
configure. In the list, there are 4 video
channels including ‘Ch#0(Internal)’ or
‘Ch#1(External)’ that administrator
selected at ‘System Management’
page.
If administrator selected ‘ Ch#0(Internal)’ at
‘System Management ’ page, 4 video channels
of ‘Ch#0, 2, 3, 4’ appear here.
If administrator selected ‘Ch#1(External) at
‘System Management’ page, 4 video channels
of ‘Ch#1, 2, 3, 4’ appear here.
WebEye E10
Different from WebEye E104, WebEye E10 has only two channels as
‘Ch#0(Internal)’ and ‘Ch#1(External)’. ‘Ch#0(Internal)’ is fixed for internal
CCD module, and ‘ Ch#1(External)’ is for external CCD camera.
(2) Video Channel State Control
Administrator decides whether to utilize video signal from selected channel in WebEye or not. If
user disables a channel with an external camera connecting to WebEye, WebEye does not show any
image from the channel. If user enables a channel without connecting an external camera to
WebEye, WebEye is interrupted and cannot transmit image properly (
transmission speed of total
channels go down
).
(3) Camera Color Type
It is to define every camera whether it is color or B/W camera. This is not to change its original
character but only to define the character and give information to WebEye.
(4) Video Signal Type
It is to define CCD module of WebEye and external CCD cameras between ‘NTSC’ and ‘PAL’.
(5) Camera Installation Angle
WebEye can always show images in right angle regardless its installation position. If
WebEye is located on the wall upside down, user can adjust image angel by
selecting ’90 deg.’ or ‘270 deg.’