(motion detection), sensor 1, sensor 2, sensor3, and sensor 4. If administrator clicks on sensor1,
e-mail is sent when the sensor1 detects events. (To utilize sensor input detection, a sensor should be
connected to WebEye.) If administrator clicks on periodic sending, e-mail is sent periodically every
preset time. The interval may be modified.
File name
: With the images of MD and Sensor event, a file is named combining all options. And
with the image of periodic sending event, administrator may decide how to name image files among
three methods. Administrator names a file with data & time (DATETIME; E.g
IMG-CH00-2001030-223031.eye) or serial number (SEQNUM; E.g. IMG-CH00-SN1.eye). Also
administrator names the file with a fixed one (Manually assigned filename). The image file has its
extension of ‘eye’ so that the file is to be reproduced on Internet browser. With DATETIME or
SEQNUM format, WebEye automatically put its extension as eye. When a file name is set manually,
make sure to put its extension with ‘eye’ (e.g. manual.eye). If not, the file cannot be reproduced on
Internet browser or other program.
Image quality
: Administrator may set image’s resolution that is delivered by e-mail. Resolution is
to be set among 90x60, 180x121, 360x243, 720x243, and 720x486. An image of 90 by 60 is of the
lowest resolution and the smallest size.
(5) FTP directory configuration
Administrator assigns FTP server address, FTP user account, FTP user password, and FTP user path
to receive files when events occur.
(6) FTP event configuration
Administrator may set sending conditions, image resolution, and filename. Image resolution,
filename, and sending conditions setting methods for FTP are same as that of e-mail.
Check Points for E-mail Sending Problem
If you have problem in sending e-mail, check followings;
•
If you have set DNS address properly in ‘System Configuration’ page.
•
If you have set sender’s e-mail address properly in ‘Application Configuration’ page.
•
If you have set e-mail type properly between ‘Base64’ and ‘Quoted Printable’.
Transmission Performance of E-mail and FTP
•
WebEye sends send once in five minutes at most when administrator configures
WebEye to send e-mail periodically. If there is no restriction in sending e-mail,
WebEye may cause a serious problem to the recipient’s mail server. However there is
no limit in sending e-mails under MD or sensor activated situation.
•
With FTP function, there is no limit. And if the periodic sending menu is set as
zero(0), WebEye transmits files at its best performance .