ELAC LAZ 5200 – Operating Instructions
Troubleshooting and Remedy
106 / 134
Wärtsilä ELAC Nautik GmbH
TH 52 614 8001 EN Rev. A 09/2018
R
efer to pr
otection
notice ISO 16016
Position data are
not displayed in
the status bar
1) No connection to
the GPS
Check cable con-
nections
Restore cable con-
nections
2) GPS transmits
incorrect data
sets
Check GPS data
sets (device ac-
cepts only valid
NMEA sets GGA
and GLL)
Set correct GPS
sets; reboot Naviga-
tion Echo Sounder
ELAC LAZ 5200, if
necessary
3) Internal software
error
---
Reboot Navigation
Echo Sounder
ELAC LAZ 5200; if
the fault persists,
contact the manufac-
turer’s service de-
partment
4) Wrong transmis-
sion group
Check set trans-
mission group
Configure transmis-
sion group according
to the on-board net-
work
and reboot the de-
vice, if necessary
Alarms are not
muted / confirmed
1) Wrong transmis-
sion group
Check set trans-
mission group
Configure transmis-
sion group according
to the on-board net-
work
and reboot the de-
vice, if necessary
Fault
Fault source
Troubleshooting
Remedy
Tab. 7.1: Troubleshooting and Remedy