Diagnostic Trouble Codes
Group 30: Electrical system
34
MID 128, PID 45
Inlet air heater status
MID 128: Engine control unit
FMI 3:
The voltage exceeds the normal value or is
short circuited to higher voltage.
FMI 4:
The voltage is less than the normal value or
is short circuited to lower voltage.
FMI 5:
The current is less than the normal value or
is open circuited.
FMI
Fault code explanation
3, 4, 5
Faulty sensor / Faulty sensor circuit
Fault indication
DCU:
Engine warning in DCU display.
CIU:
Flash code
Flash code
Electrical fault: 5.4
Value fault:
None
Symptom
FMI 3, 5:
Preheat relay never activated. White
smoke for cold start. Start problems in
cold climate.
FMI 4:
Induction air is hot. Preheat relay is im-
possible to turn off. Preheat fuse will
break.