Diagnostic Trouble Codes
Group 30: Electrical system
120
FMI 5 The current is less than the normal
value or is open circuited
Possible reason:
•
An open circuit in one or both cables from EMS 2
to MPROP.
•
Short circuit to battery negative in MPROP posi-
tive wire, pin 1 on MPROP.
•
Short circuit between both wires to MPROP.
•
Short circuit to battery voltage in MPROP positive
wire, pin 1 on MPROP.
Suitable action:
1.
Check contact pressure in socket 12 and 16 in
engine connector A. Also check contact pressure
in connector at MPROP.
2.
Check cable harness and connectors between
EMS 2 and MPROP.
FMI 6 The current is greater than the
normal value or is short circuited to
battery negative
Possible reason:
•
Short circuit to battery negative in MPROP nega-
tive cable, pin 2 on MPROP.
•
An open circuit in one or both cables from EMS 2
to MPROP.
Suitable action:
1.
Check contact pressure in socket 12 and 16 in
engine connector A. Also check contact pressure
in connector at MPROP.
2.
Check cable harness and connectors between
EMS 2 and MPROP
FMI 13
Possible reason:
•
Short circuit to battery negative in MPROP nega-
tive cable, pin 2 on MPROP.
Suitable action:
1.
Check cable harness and connectors between
EMS 2 and MPROP.