Group 30: Electrical system
Diagnostic Trouble Codes
91
FMI 5 Abnormally low current or open
circuit
Possible reason:
•
An open circuit in one or both of the cables to the
IEGR.
Suitable action:
1.
Check cable harness and connectors between
EMS 2 and IEGR.
2.
Check IEGR coil.
FMI 7 Mechanical fault
Possible reason:
•
IEGR solenoid mechanically stucked.
•
Too low oil pressure to activate the IEGR.
Suitable action:
1.
Check function of IEGR solenoid.
2.
Check engine oil pressure.
Measurements
NOTE!
If any of the measurements shows an abnor-
mal value, check the wiring to and from the engine in-
terface.
Checking the wiring:
1.
NOTE!
Cut the current with the main switch.
2.
Remove the connector to the IEGR solenoid.
3.
Remove connector B from the EMS 2.
4.
Connect the B connector to brakeout cable
9990014 with measurebox 9998699.
5.
Use multimeter 9812519 to do a resistance mea-
surement.
Measurement points in box
Nominal value
30 (IEGR signal) -
R
≈
0
Ω
2 (IEGR connector)
57, 60 (relay +) -
R
≈
0
Ω
1 (IEGR connector)