Diagnostic Trouble Codes
Group 30: Electrical system
96
Fault tracing
NOTE!
If the control panel ONLY communicates on
the J1939 communication and NOT the redundancy of
J1587 for start, stop and throttle this fault code is ac-
tive in the VODIA and that is normal.
FMI 9
Fault condition:
“Time-out” on the J1587 bus.
Possible reason:
•
Fault in the communication with the DCU/CIU.
•
No DCU/CIU found.
•
Open circuit in the power supply cable between
the engine control unit and the DCU/CIU.
•
Faulty DCU/CIU.
Suitable action
1.
Check communication cables to the DCU/CIU.
2.
Check power supply cable between engine control
unit and DCU/CIU.
3.
Check that DCU/CIU is programmed for correct
engine type.