Diagnostic Trouble Codes
Group 30: Electrical system
68
FMI 4 Abnormally low voltage or short
circuit to lower voltage
Conditions for fault code:
The voltage on pin B18 on the EMS 2 is less than 0.07
Volt.
Possible reason:
•
Short circuit between both cables to the coolant
temperature sensor.
•
Faulty sensor.
Suitable action:
1.
Check cable harness and all connectors between
coolant temperature sensor and EMS 2.
2.
Check function of coolant temperature sensor.
FMI 5 Abnormally low current or open
circuit
Conditions for fault code:
The voltage on pin B27 on the EMS 2 is more than
4.95 Volt.
Possible reason:
•
Open circuit in signal cable to temperature sen-
sor.
•
Open circuit in negative cable to temperature sen-
sor.
•
Faulty sensor.
Suitable action:
1.
Check contact pressure in socket 18 and 27 in
engine connector B. Check also contact pressure
in connector at coolant temperature sensor.
2.
Check cable harness and all connectors between
coolant temperature sensor and EMS 2.
3.
Check function of coolant temperature sensor.