Diagnostic Trouble Codes
Group 30: Electrical system
48
FMI 3 Abnormally high voltage or short
circuit to higher voltage
Conditions for fault code:
The voltage on pin B11 on the EMS 2 is more than
4.95 Volt.
Possible reason:
•
Short circuit between signal cable and 5V supply
to oil pressure sensor.
•
Faulty sensor.
Suitable action:
1.
Check cable harness and connectors between oil
pressure sensor and EMS 2.
2.
Check function of oil pressure sensor.
FMI 5 Abnormally low current or open
circuit
Conditions for fault code:
The voltage on pin B11 on the EMS 2 is less than 0.07
Volt.
Possible reason:
•
An open circuit in 5V supply cable to oil pressure
sensor.
•
An open circuit in signal cable to oil pressure sen-
sor.
•
Short circuit between signal cable and battery
negative to oil pressure sensor.
•
Faulty sensor.
Suitable action:
1.
Check contact pressure in socket 11 and 17 in
engine connector B. Also check contact pressure
in connector at oil pressure sensor.
2.
Check cable harness and connectors between oil
pressure sensor and EMS 2.
3.
Check function of oil pressure sensor.