63
Checking boost pressure sensor
•
NOTE!
Turn ignition off.
•
Disconnect the connector from the sensor
•
Connect adapter cable 885675 between the sen-
sor and the engine control unit.
•
Use multimeter 9812519 for voltage measure-
ment.
•
Turn ignition on.
Measurement points
Nominal value
1 – 4
U
≈
1,1 V (at normal
atmospheric pressure)
Component specification
Working range: 0,5 – 4,0 bar = 50 – 400 kPa
Supply voltage: 5,00 +/- 0,25 VDC
Nominal output voltage at 25 °C and at supply voltage
5,00 VDC:
0,5 VDC at 0,5 bar = 50 kPa
4,5 VDC at 4 bar = 400 kPa
Output voltage, V
Boost air pressure
(absolute pressure), kPa