Diagnostic Trouble Codes
Group 30: Electrical system
98
Fault tracing
NOTE!
If the control panel ONLY communicates on
the J1939 communication and NOT the redundancy of
J1587 for start, stop and throttle this fault code is ac-
tive in the VODIA and that is normal.
FMI 3 Abnormally high voltage or short
circuit to higher voltage
Possible reason:
•
Open circuit in any or all of the throttle signals.
•
Short circuited throttle potentiometer signal cable
to 5V voltage or to battery voltage.
•
Faulty throttle potentiometer.
Suitable action:
1.
Check that the throttle potentiometer is connected
correctly.
2.
Check cable harness and connectors between
CIU and CIU throttle potentiometer.
3.
Check function of throttle potentiometer.
4.
Check contact pressure in socket 2, 3 and 30 in
CIU connector.
FMI 4 Abnormally low voltage or short
circuit to lower voltage
Possible reason:
•
Short circuited throttle potentiometer signal cable
to battery negative.
•
Faulty throttle potentiometer.
Suitable action:
1.
Check that the throttle potentiometer is connected
correctly.
2.
Check cable harness and connectors between
CIU and CIU throttle potentiometer.
3.
Check function of throttle potentiometer.