Diagnostic Trouble Codes
Group 30: Electrical system
86
Fault tracing
FMI 3 Abnormally high voltage or short
circuit to higher voltage
Possible reason:
•
Faulty start switch.
Suitable action:
1.
Check that start switch is connected correctly.
2.
Check cable harness and connectors between
CIU and start switch.
3.
Check function of start switch.
FMI 4 Abnormally low voltage or short
circuit to lower voltage
Possible reason:
•
Short circuited CIU start signal cable to battery
negative.
•
Faulty start switch.
Suitable action:
1.
Check that start switch is connected correctly.
2.
Check contact pressure in socket 35 in the CIU
connector.
3.
Check cable harness and connectors between
CIU and start switch.
4.
Check function of start switch.