Check
- This screen is to inform the operator when a
partial failure of the machine is detected.
- The amber central warning symbol is shown.
- The buzzer sounds four times.
- Press SELECT button to obtain more information
about the malfunction.
- Alarm text is shown until confirmation is
performed by pressing ESC button.
- Repair or contact a workshop authorized by Volvo
for information.
Table. Example of check screen
Check at next stop
DBLD/X3 relay failure
Travel speed valve failure
ELEC-DBLD/X3 disabled
Speed not changeable
RH proportional switch failure
LH proportional switch failure
Boom-swing/X1 disabled
ELEC-DBLD/X3 disabled
X1 double acting valve failure
X1 single acting valve failure
X1 disabled
X1 disabled
E-ECU not responding
I-ECU not responding
Communication failure
Communication failure
Keypad not responding
CCM not responding
Communication failure
Communication failure
Starter relay failure
Conflux cutoff valve failure
Lifting mode inoperable
Boom-swing/X1 valve failure
LH/RH direction valve failure
Boom-swing/X1 disabled
Boom-swing/X1 disabled
Boom-swing/X1 PPRV failure
X3 PPRV failure
Boom-swing/X1 disabled
X3 disabled
ELEC-DBLD PPRV failure
Alternator failure
ELEC-DBLD disabled
Battery not charging
Engine air filter clogged
V-ECU not responding
Communication failure