General System Parameters
SETUP 1 (Inside SETUP Menu)
VT200/220 Technical Manual, Rev 1.00.01
48
Doc
#
TM-VT200/220-EN
To edit parameters in the SETUP 1 menu:
1. The current parameter number is shown on the display. Use
( ) to scroll to
the parameter you need (see the following section for descriptions of parameters).
2. To edit the parameter value, use
P.TARE
(
) to increment the current digit and
TARE
( ) to move to the next digit.
3. When the display is showing the required value, press
( ) to confirm your
selection.
5.2.2
SETUP 1 Parameters
Parameters 1.2, 1.3, 1.5 and 1.7 are not in use in this version of the
VT200/220, and so are not detailed in the table below.
Par. Description
Values
1.1 Enable
totalizer
. YES enables the totalizer. NO disables it.
0=NO 1=YES
1.4 Date
format
. Sets the date format in all printing formats.
0=d-m-y 1=m-d-y
1.6 Enable
battery-backed
RAM
. If the battery-backed RAM option is
installed, this parameter enables saving date, time and the
accumulated total in persistent memory.
You must enable this parameter to be able to set date and time.
0=NO 1=YES
1.8
Enable function menu
.
YES specifies that users can access the function menu by pressing
TARE
for 3 seconds.
NO specifies that users should not be able to access the function
menu.
0=NO 1=YES
1.t Auto
power
off
. Time for the unit to switch off if the scale is zero.
00-99 minutes
00=Disabled
1.E
Number of samples in counting
. 5-99