Display, Keys and Menus
Setup Menus
VT200/220 Technical Manual, Rev 1.00.01
32
Doc
#
TM-VT200/220-EN
3.4.2
Menu Structure
Main menu
Submenu
Description
SETUP SETUP
1
General scale parameters.
SETUP
2
Serial port 1 parameters.
SETUP
3
Serial port 2 parameters.
SETUP
4
Tilt Switch parameters.
SETUP
5
Setpoint parameters.
SETUP
6
Lock keys.
Par
0.P, 1.P, 2.P, 3.P, 4.P, 5.P, 6.P, 7.P
General scale parameters with multiple values.
8.1, 8.2, 8.3, 8.4, 8.5, 8.6, 8.7, 8.8, 8.9,
8.A, 8.b
General scale parameters with two possible
values.
CAL S-CAL
(ZEro,
SPAN)
Standard-weights calibration dialog.
E-CAL
(ZEro,
SPAN)
Electronic calibration dialog.
STORE -
Permanently saves calibration data and exits
setup.
INIT -
Resets scale parameters, configuration and
calibration data to manufacturer defaults.
A-CAL
A.1, A.2, A.3, A.4, A.5, A.6, A.7, A.8
D/A analog output parameters.
3.4.3
Parameter Summary
SETUP > SETUP 1 (General Operating Parameters)
Par. Description
Values
1.1
Enable totalizer
. YES enables the totalizer. NO disables it.
0=NO 1=YES
1.4
Date format
. Sets the date format in all printing formats.
0=d-m-y 1=m-d-y
1.6
Enable real-time clock and battery-backed RAM (optional)
.
If the battery-backed RAM option is installed, this parameter enables
saving date, time and the accumulated total in persistent memory.
You must enable this parameter to be able to set date and time.
0=NO 1=YES
1.8
Enable function menu
.
YES specifies that users can access the function menu by pressing
TARE
for 3 seconds.
NO specifies that users should not be able to access the function
menu.
0=NO 1=YES