
Display, Keys and Menus
Setup Menus
VT200/220 Technical Manual, Rev 1.00.01
34
Doc
#
TM-VT200/220-EN
Par Description
Values
2.8
Operator print type change
(Fn 20-
30).
0=NO 1=YES
2.d
Data bits/Parity serial channel 1
N8 = 8 Data bits/no parity, 07 = 7 Data bits/odd
parity, E7 = 7 Data bits/even parity,
2.11
1 line with date, time and indicated
weight
07-10-03 15:25:20 00500kgG
0=NO 1=YES
2.b
Baud rate serial channel 1.
12= 1200 bps
24= 2400 bps
48 = 4800 bps
96 = 9600 bps
Above
2.2
,
2.b
and
2.d
settings only suitable to set
2.t
=0.2 for Continuous
Weight Output.
SETUP > SETUP 3 (Com 2 Settings)
Par.
Description
Values
3.t
Instrument communication type.
00=disabled; 01 =continuous weight output;
02=EDP protocol output; 03=printer protocol output;
06=continuous weight w/tare output; 11=continuous
output with dual scale; 65-89=master/slave protocol
address
3.1
Timeout control.
0=NO 1=YES
3.2
Handshake.
0=NO 1=YES
3.3
Operator disable.
0=NO 1=YES
3.4
Host enquiry.
0=NO 1=YES
3.5
Remote keyboard commands.
0=NO 1=YES
3.6
Continuous weight output format
LEO or AND
3.7
(Reserved for future use)
3.8
Debug.
0=NO 1=YES
3.b
Baud rate serial number 2.
24 = 2400 bps
96 = 9600 bps
19 = 19200 bps
38 = 38400 bps
57 = 57600 bps