Display, Keys and Menus
Setup Menus
VT200/220 Technical Manual, Rev 1.00.01
35
Doc
#
TM-VT200/220-EN
3.d
Data bits serial channel 2.
17 = 7 data bits / even parity
08 = 8 data bits / no parity
18 = 8 data bits / even parity
SETUP > SETUP 4 (Tilt Switch)
Par. Description
Values
4.t
Time delay, after closing the contact, for the display to lock. This is
also the time for the display to unlock after the contact is opened.
This parameter allows several special options, accessed by setting it
above
90
:
•
91
– Tare scale on the rising edge of input. Setpoints always
enabled.
•
92
– Print on the rising edge of the input. Setpoints always
enabled.
•
93
– Setpoints active when input is high. Setpoints inactive when
input is low.
•
94
– Scale is tared at the rising edge of input. If taring is
successful, setpoints are activated. If input is low, setpoints are
inactive.
•
95
– When input is low, scale 1 is selected and displayed. When
input is high, scale 2 is selected and displayed.
•
96 – Scale is zeroed.
00=disabled
01-90 (x o.1 sec)
91-96=special options
SETUP > SETUP 5 (Setpoints)
Par.
Description
Values
5.1, 5.2
Setpoint 1 output.
5.1=0 and 5.2=0: normal
5.1=1 and 5.2=0: no motion
5.1=0 and 5.2=1: error
5.3, 5.4
Setpoint 2 output.
5.3=0 and 5.4=0: normal
5.3=1 and 5.4=0: zero
5.3=0 and 5.4=1: net
5.6
Net / gross
for both setpoints.
0 = net
1 = gross
5.7
Normally open / closed for both setpoints.
0 = normally open
1 = normally closed