90
20 BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BALANCE Gain Flag
02H
DATA02: BALANCE Gain
EAH: -22
|
FFH: -01
00H: 0
01H: +01
|
16H: +22
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BALANCE Gain Flag
02H
21 ASPECT RATIO SELECT
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH
80H
60H
51H
01H
DATA00 CKS
DATA00: 02H: I-WIDE
03H: LTR BOX
04H: STD 4:3
05H: ANAMPHC
ACK
7FH
60H
80H
51H
01H
DATA00 CKS
DATA00: 02H: I-WIDE
03H: LTR BOX
04H: STD 4:3
05H: ANAMPHC