91
22 V SHIFT GAIN DATA
Function
The external control equipment changes the V SHIFT gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V SHIFT Gain Flag
01H
DATA02: V SHIFT Gain
C0H: -64
|
FFH: -01
00H: 0
01H: +01
|
40H: +64
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: V SHIFT Gain Flag
01H
23 H SHIFT GAIN DATA
Function
The external control equipment changes the H SHIFT gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: H SHIFT Gain Flag
02H
DATA02: H SHIFT Gain
80H: -128
|
FFH: -01
00H: 0
01H: +01
|
7FH: +127
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
03H
DATA01: H SHIFT Gain Flag
02H