16 BLUE GAIN DATA
Function
The external control equipment changes the BLUE gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
04H
DATA00 to DATA03 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BLUE Gain Flag
03H
DATA02: BLUE Gain 1 (Offset)
D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
DATA03
BLUE Gain 2 (Drive)
D8H: -40
|
FFH: -1
00H: 0
|
IEH: +30
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BLUE Gain Flag
03H
17 VID NR MODE SET
Function
The external control equipment sets the VID NR (Noise Reduction) mode of the plasma
monitor.
Transmission Data
DFH
80H
60H
C0H
01H
DATA00 CKS
DATA00: 01H: VID NR OFF
02H: VID NR-1
03H: VID NR-2
04H: VID NR-3
ACK
7FH
60H
80H
C0H
01H
DATA00 CKS
DATA00: 01H: VID NR OFF
02H: VID NR-1
03H: VID NR-2
04H: VID NR-3
External Controls