89
18 BASS GAIN DATA
Function
The external control equipment changes the BASS gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BASS Gain Flag
03H
DATA02: BASS Gain
F3H: -13
|
FFH: -01
00H: 0
01H: +01
|
ODH: +13
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BASS Gain Flag
03H
19 TREBLE GAIN DATA
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: TREBLE Gain Flag
04H
DATA02: TREBLE Gain
F3H: -13
|
FFH: -01
00H: 0
01H: +01
|
0DH: +13
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: TREBLE Gain Flag
04H