External Controls
48 FAILURE MODE REQUEST
Function
The external control equipment inquires the detection of failures of the plasma monitor.
Transmission Data
1FH
80H
60H
3FH
00H
CKS
ACK
The plasma monitor returns the following ACK:
7FH
60H
80H
3FH
02H
DATA00 DATA01 CKS
DATA00: FAILURE MODE 1
Bit 0:
PDP MODULE
0: Abnormal
1: Normal
Bit 1:
1: fixed (backup)
Bit 2:
TEMPERATURE
0: Abnormal
1: Normal
Bit 3:
1: fixed (backup)
Bit 4:
TEMPERATURE SENSOR
0: Abnormal
1: Normal
Bit 5:
1: fixed (backup)
Bit 6:
1: fixed (backup)
Bit 7:
1: fixed (backup)
DATA01: FAILURE MODE 2
1: fixed (backup)
49 MODEL NAME REQUEST
Function
The external control equipment inquires the product code of the plasma monitor.
Transmission Data
1FH
80H
60H
17H
00H
CKS
ACK
The plasma monitor returns the following ACK:
7FH
60H
80H
17H
0CH
DATA00 to DATA11
CKS
DATA00: 1st character of the product code
DATA01: 2nd character of the product code
|
DATA11: 12th character of the product code
NOTE:
Received Data (Hex)
Corresponding Character
00H
0
01H
1
|
|
08H
8
09H
9
10H
A
11H
B
12H
C
|
|
28H
Y
29H
Z
80H
- (Hyphen)
96H
(Blank)
If there are fewer than 12 characters in the product code,
product code would be padded right with blanks.
105
Summary of Contents for PlasmaView VP-42
Page 1: ...VP 42 VP 42HD VP 50 VP 60 Owner s Manual...
Page 114: ...113 DIMENSIONS 40 301 1 665 24 220 4 899 1 474 42 diagonal VP 42 VP 42HD...
Page 115: ...114 Dimensions 2 172 48 407 29 286 1 667 3 941 50 diagonal VP 50...
Page 116: ...115 Dimensions 2 227 58 117 34 912 4 855 1 903 60 diagonal VP 60...