EXTERNAL CONTROL                          NEC LCD Monitor 

Rev.2.6 

INDEX

 

I. Application

................................................................................3

 

II. Preparation

...............................................................................4

 

2. Connectors and wiring

....................................................................4

 

2.1 RS-232C Remote control

...............................................................4

 

2.2 LAN control

...........................................................................4

 

III. Communication specification

...............................................................5

 

3. Communication Parameter

................................................................5

 

3.1 RS-232C Remote control

...............................................................5

 

3.2 LAN control

...........................................................................5

 

3.3 Communication timing

.................................................................5

 

4. Communication Format

...................................................................6

 

4.1 Header block format (fixed length)

......................................................7

 

4.2 Message block format

.................................................................9

 

4.3 Check code

..........................................................................11

 

4.4 Delimiter

............................................................................12

 

5. Message type

...........................................................................13

 

5.1 Get current Parameter from a monitor.

.................................................13

 

5.2 "Get parameter" reply

.................................................................14

 

5.3 Set parameter

........................................................................15

 

5.4 "Set parameter" reply

.................................................................16

 

5.5 Commands

...........................................................................17

 

5.5.1

 

Save Current Settings

. ............................................................17

 

5.5.2 Get Timing Report and Timing reply.

................................................18

 

5.5.3 NULL Message

....................................................................19

 

IV. Control Commands

.......................................................................20

 

6. Typical procedure example

...............................................................20

 

6.1. How to change the 

Backlight

 setting.

................................................20

 

6.2. How to read the measurement value of the built-in temperature sensors.

..................23

 

6.3. Operation Code (OP code) Table

.......................................................26

 

7. Power control procedure

.................................................................35

 

7.1 Power status read

....................................................................35

 

7.2 Power control

........................................................................37

 

8. Asset Data read and write

................................................................39

 

8.1 Asset Data Read Request and reply

....................................................39

 

8.2 Asset Data write

.....................................................................41

 

Summary of Contents for MultiSync V422

Page 1: ...sage type 13 5 1 Get current Parameter from a monitor 13 5 2 Get parameter reply 14 5 3 Set parameter 15 5 4 Set parameter reply 16 5 5 Commands 17 5 5 1 Save Current Settings 17 5 5 2 Get Timing Repo...

Page 2: ...Read 48 10 2 Schedule Write 53 11 Self diagnosis 63 11 1 Self diagnosis status read 63 12 Serial No Model Name Read 65 12 1 Serial No Read 65 12 2 Model Name Read 66 13 Security Lock 67 13 1 Security...

Page 3: ...I Application This document defines the communications method for control of the NEC LCD monitor MultiSync P402 P462 P552 P702 V422 V462 V551 V651 X461S X551S X463UN X551UN when using an external cont...

Page 4: ...ub Cable Cross reversed cable or null modem cable Please refer Controlling the LCD monitor via RS 232C Remote control on User s manual 2 2 LAN control Connector RJ 45 10 100 BASE T Cable Category 5 or...

Page 5: ...ication layer Transport layer TCP Using the payload of TCP segment 4 IP address Default 192 168 0 10 If you need to change Please refer Network settings on User s manual 5 Port No 7142 Fixed Note The...

Page 6: ...ed item The controller sends commands to set an adjusted value The monitor replies to the controller for confirmation The controller sends command to get a value for confirmation The monitor replies a...

Page 7: ...60h 57 79h 82 92h 8 48h H 33 61h 58 7Ah 83 93h 9 49h I 34 62h 59 7Bh 84 94h 10 4Ah J 35 63h 60 7Ch 85 95h 11 4Bh K 36 64h 61 7Dh 86 96h 12 4Ch L 37 65h 62 7Eh 87 97h 13 4Dh M 38 66h 63 7Fh 88 98h 14...

Page 8: ...ck format for more details ASCII A 41h Command ASCII B 42h Command reply ASCII C 43h Get current parameter from a monitor ASCII D 44h Get parameter reply ASCII E 45h Set parameter ASCII F 46h Set para...

Page 9: ...ntroller sends this message to change a setting of the monitor Message format of the Set parameter is as follows Refer to section 5 3 Set parameter for more details 4 Set Parameter reply The monitor r...

Page 10: ...5 5 Commands message for more details 6 Command reply The monitor replies to a query from the controller Command reply message format depends on each command Refer to section 5 5 Commands message for...

Page 11: ...h xor 30h xor 31h xor 30h xor 30h xor 30h xor 36h xor 34h xor 03h 77h Header Message Check code Delimiter 27 26 25 24 23 22 21 20 SOH D0 Reserved D1 Destination D2 Source D3 Type D4 Length H D5 Length...

Page 12: ...12 71 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter...

Page 13: ...OP code page data must be encoded to ASCII characters Ex The byte data 02h must be encoded to ASCII characters 0 and 2 30h and 32h OP code page 02h OP code page Hi ASCII 0 30h OP code page Lo ASCII 2...

Page 14: ...ese bytes indicate a replying item s OP code This returned value from the monitor is encoded to ASCII characters Refer to the operation code table Ex The byte data 1Ah is encoded to ASCII character 1...

Page 15: ...and 2 30h and 32h Refer to the Operation code table 4th 5th bytes OP code Operation code This OP code data must be encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A...

Page 16: ...r is encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A 41h Refer to Operation code table 8th 9th bytes Type Operation type code ASCII 0 0 30h 30h Set parameter ASCII...

Page 17: ...quests for the monitor to store the adjusted value Send OC 30h 43h as Save current settings command Complete Save Current setting command packet as follows ASCII 01h 30h 41h 30h 41h 30h 34h 02h 30h 43...

Page 18: ...ies status as the following format SS Timing status byte Bit 7 1 Sync Frequency is out of range Bit 6 1 Unstable count Bit 5 2 Reserved Don t care Bit 1 1 Positive Horizontal sync polarity 0 Negative...

Page 19: ...r not expected Following operations need a certain time for to execute so the monitor will return this message when another message is received during execution Power ON Power OFF Auto Setup Input PIP...

Page 20: ...03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 2 The monitor replies with current Backlight setting a...

Page 21: ...ontroller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 F 46h Message Type is Set parameter reply 1 2 31h 32h Message length is 18 bytes Message...

Page 22: ...re the setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller A 41h Message type is Command 0 4 30h 34h Message length is 4 bytes Message STX 02h Start of Message 0 C 30h 43h C...

Page 23: ...37h 38h Operation code is 78h on page 2 0 0 0 1 30h 30h 30h 31h Select the temperature sensor 1 01h 00h No meaning 01h Sensor 1 02h Sensor 2 03h Sensor 3 ETX 03h End of Message Check code BCC Block C...

Page 24: ...2 30h 32h Operation code page number is 2 7 9 37h 39h Operation code is 79h in the page 2 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculat...

Page 25: ...code for a BCC calculation Delimiter CR 0Dh End of packet Readout value Temperature Celsius Binary Hexadecimal 125 0 0000 0000 1111 1010 00FAh 25 0 0000 0000 0011 0010 0032h 0 5 0000 0000 0000 0001 0...

Page 26: ...0 100 64h center 200 C8h Gamma Correction 02h 68h Gamma Table Selection 1 Native Gamma 4 Gamma 2 2 8 Gamma 2 4 7 S Gamma 5 DICOM SIM 6 Programmable Adaptive Contrast 02h 8Dh 0 None 1 Off 2 Low 3 Middl...

Page 27: ...ide Max Right side Depends on a display timing V Position 00h 30h 0 Bottom side Max Top side Depends on a display timing Clock 00h 0Eh 0 Max Phase 00h 3Eh 0 Max H Resolution 02h 50h 0 Low Max High V R...

Page 28: ...CDh 0 Down side Max Up side Menu tree reset Adjust 02h CBh 0 None 3 Reset Adjust category Momentary Volume 00h 62h 0 whisper 100 loud 00h Balance 00h 93h O Left 30 Center 60 Right Not available on X55...

Page 29: ...ary Keep PIP Mode 10h 82h 0 No operate 1 Off 2 On PIP Mode 02h 72h 1 Off 2 PIP 3 POP 4 Still 5 Side by side aspect 6 Side by side Full 7 reserved 8 reserved PIP Size 02h 71h 1 Small 2 Middle 3 Large P...

Page 30: ...anguage 00h 68h 1 English 2 German 3 French 4 Spanish 5 Japanese 6 Italian 7 Swedish 9 Russian 14 0Eh Chinese OSD Language Menu Display Time 00h FCh 0 1 Do not set 2 10s 3 15s 48 240s 5sec step H Posi...

Page 31: ...e Off 2 Enable On Tile Matrix Mode 02h D3h 1 Disable Off and display frame 2 Enable On 3 Disable Off and erase frame Set only Power On Delay 02h D8h 0 Off 0sec 50 50sec Power Indicator 02h BEh 0 None...

Page 32: ...ect 2 None 3 VIDEO detect 4 Custom detect Priority1 10h 2Eh Priority2 10h 2Fh Priority3 10h 30h Priority4 10h 31h Custom Detect Priority5 10h 32h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 Video...

Page 33: ...eo1 6 Video2 7 S Video 12 0Ch DVD HD1 13 0Dh Option 14 0Eh DVD HD2 15 0Fh Display Port 17 11h HDMI Audio Input 02h 2Eh 1 Audio 1 PC 2 Audio 2 3 Audio 3 4 HDMI 6 TV Option 7 Display Port Volume UP Down...

Page 34: ...tion has limitation of selection Please refer to the monitor instruction manual Still Capture 02h 76h 0 Off 1 Capture Momentary Signal Information 02h EAh 0 No Action 1 Off No indication 2 On Indicati...

Page 35: ...the current power status Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Mo...

Page 36: ...36 71 CR 0Dh End of packet...

Page 37: ...rved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message lengt...

Page 38: ...38 71 Delimiter CR 0Dh End of packet...

Page 39: ...area 2 0 32h 30h Read out data length is 32bytes Secondly set 20h Read data from the 32bytes offset point in the Asset data area Maximum readout length is 32bytes at a time ETX 03h End of Message Che...

Page 40: ...40 71 Delimiter CR 0Dh End of packet...

Page 41: ...d of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a data for confirmation Header Message Check...

Page 42: ...42 71 CR 0Dh End of packet...

Page 43: ...heck code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the controller Header Message Check code Deli...

Page 44: ...h 35h Friday 0 6 30h 36h Saturday HH Hours 0 0 30h 30h 0 1 7 31h 37h 23 17h MN Minutes 0 0 30h 30h 0 3 B 33h 42h 59 3Bh DS Daylight saving Summer time 0 0 30h 30h NO 0 1 30h 31h YES ETX 03h End of Mes...

Page 45: ...h Message STX 02h Start of Message C 2 1 2 43h 32h 31h 32h Date Time write command YY MM DD WW HH MN DS Date Time data YY Year offset 2000 0 0 30h 30h 2000 6 3 36h 33h 2099 99 63h MM Month 0 1 30h 31h...

Page 46: ...e write reply command ST Date Time Status command 0 0 30h 30h No error 0 1 30h 31h Error YY MM DD WW HH MN DS Date Time data YY Year offset 2000 0 0 30h 30h 2000 6 3 36h 33h 2099 99 63h MM Month 0 1 3...

Page 47: ...47 71 Delimiter CR 0Dh End of packet...

Page 48: ...Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Schedule to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 2 6 STX C 3 2 1 PG ON HOUR ON...

Page 49: ...Port 1 1 31h 31h HDMI WD Week setting bit 0 Monday bit 1 Tuesday bit 2 Wednesday bit 3 Thursday bit 4 Friday bit 5 Saturday bit 6 Sunday EX 0 1 30h 31h Monday 0 4 30h 34h Wednesday 0 F 30h 46h Monday...

Page 50: ...onitor it is always 00 EXT5 Extension 5 0 0 30h 30h On this monitor it is always 00 EXT6 Extension 6 0 0 30h 30h On this monitor it is always 00 EXT7 Extension 7 0 0 30h 30h On this monitor it is alwa...

Page 51: ...r to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Schedule to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 6 STX C...

Page 52: ...orks on last memory WD Week setting bit 0 Monday bit 1 Tuesday bit 2 Wednesday bit 3 Thursday bit 4 Friday bit 5 Saturday bit 6 Sunday EX 0 1 30h 31h Monday 0 4 30h 34h Wednesday 0 F 30h 46h Monday Tu...

Page 53: ...es command PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time...

Page 54: ...1 30h 31h sRGB 0 3 30h 33h Hi Bright 0 4 30h 34h Standard 0 5 30h 34h Cinema 0 6 30h 36h ISF Day 0 7 30h 37h ISF Night 0 B 30h 42h Ambient 1 0 C 30h 43h Ambient 2 Please select active picture mode on...

Page 55: ...rror 0 1 30h 31h Error PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR...

Page 56: ...ndard 0 5 30h 34h Cinema 0 6 30h 36h ISF Day 0 7 30h 37h ISF Night 0 B 30h 42h Ambient 1 0 C 30h 43h Ambient 2 EXT1 Extension1 0 0 30h 30h On this monitor it is always 00 EXT2 Extension 2 0 0 30h 30h...

Page 57: ...a BCC calculation Delimiter CR 0Dh End of packet 4 The monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 0...

Page 58: ...58 71 Delimiter CR 0Dh End of packet...

Page 59: ...G ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON...

Page 60: ...ID B 1 8 STX C 3 1 4 ST PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying...

Page 61: ...L Option bit 0 0 once 1 Everyday bit 1 0 once 1 Every week bit 2 0 Disable 1 Enable When bit 0 and bit 1 are 1 it behaves as Everyday EX 0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once ETX 03h En...

Page 62: ...1h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Co...

Page 63: ...essage receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The m...

Page 64: ...64 71 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet...

Page 65: ...CR 0Dh End of packet 2 The monitor replies the serial No data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX C 3 1 6 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h...

Page 66: ...et 2 The monitor replies the model name data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX C 3 1 7 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h Start Of Header 0...

Page 67: ...orID 0 A 1 0 STX C 2 1 D EN P1 P2 P3 P4 ETX BCC CR Header SOH 01h Start Of Header 0 30h Reserved Monitor ID Specify the Monitor ID of which you want to change a setting Ex If Monitor ID is 1 specify A...

Page 68: ...nitor ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length Message STX 02h Start of Message C 3 1 D 43h 33h 31h 44h Security Lock Control reply command ST EN Lock condition result da...

Page 69: ...k Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result to the controller Header Message Check code Delimiter SOH 0 0 Mon...

Page 70: ...Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result to the controller Header Message Check code De...

Page 71: ...is document provides the technical information for users NEC Display Solutions Ltd reserves the right to change or modify the information contained herein without notice NEC Display Solutions Ltd make...