(21/71)
CR (0Dh): End of packet
Step 3. The controller request the monitor to change the Backlight setting
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'E' (45h): Message Type is "Set parameter command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Backlight setting 80(0050h).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
“
Check code
”
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 4. The monitor replies with a message for confirmation.
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'F' (46h): Message Type is "Set parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Backlight max value is 100(0064h).
'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Backlight setting was 80(0050h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
“
Check code
”
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Repeat Step 1 and Step 2, if you need to check the Backlight setting. (Recommended)
Step 5. Request the monitor to store the Backlight setting. (Save Current Settings Command)
Header
Message
Check
code
Delimiter
SOH-'0'-Monitor ID-'0'-'E'-'0'-'A'
STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX
BCC
CR
Header
Message
Check code
Delimiter
SOH-'0'-'0'- Monitor ID -'F'-'1'-'2'
STX-'0'-'0'-'0'-'0'-'1'-'0'
—
'0'-'0'-'0'
-'0'-'6'-'4'-'0'-'0'-'5'-'0'-ETX
BCC
CR
Summary of Contents for MultiSync V422
Page 12: ...12 71 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter...
Page 36: ...36 71 CR 0Dh End of packet...
Page 38: ...38 71 Delimiter CR 0Dh End of packet...
Page 40: ...40 71 Delimiter CR 0Dh End of packet...
Page 42: ...42 71 CR 0Dh End of packet...
Page 47: ...47 71 Delimiter CR 0Dh End of packet...