6. Typical procedure example
The following is a sample of procedures to control the monitor, these are examples of "Get parameter",
"Set parameter" and "Save current settings".
6.1. How to change the
“
Backlight
”
setting.
Step 1. The controller requests the Monitor to reply with the current brightness setting and capability
to support this operation. (Get parameter)
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-'0'-'C'-'0'-'6'
STX-'0'-'0'-'1'-'0'-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message type is "Get parameter command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the OP code page 0).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
“
Check code
”
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies with current Backlight setting and capability to support this operation.
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Backlight max value is 100(0064h).
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Backlight setting is 50(0032h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
“
Check code
”
for a BCC calculation.
Delimiter
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'
STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'
-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX
BCC
CR
Summary of Contents for MultiSync V422
Page 12: ...12 71 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter...
Page 36: ...36 71 CR 0Dh End of packet...
Page 38: ...38 71 Delimiter CR 0Dh End of packet...
Page 40: ...40 71 Delimiter CR 0Dh End of packet...
Page 42: ...42 71 CR 0Dh End of packet...
Page 47: ...47 71 Delimiter CR 0Dh End of packet...