J0 [RS]: Regenerator section trace
Program a 1 or 16-byte identifier to check the connection between regenerators
J1 [HP]: High order path section trace
Program a 16 or 64-byte identifier to check the high order transmission path
J2 [LP]: Low order path section trace
Program a 16 or 64-byte identifier to check the low order transmission path
Copy:
This function allows copying the received trace identifier from RX, making it easier on the user, specially for the longer strings, to minimize typos.
Note:
To program or edit the transmitted trace, tap the applicable trace box to display the pop-up keyboard.
TX - JO [RS]
7.5.4.2 Received Traces (RX)
J0 [RS]: Regenerator section trace
Program a 1, 16-byte or 64-byte identifier to set and check the expected trace
Enable or disable the TIM (Trace Identifier Mismatch) alarm
J1 [HP Path]: High order path section trace.
Program a 16 or 64-byte identifier to set and check the expected trace
Enable or disable the TIM (Trace Identifier Mismatch) alarm
J2 [LP Path]: Low order path section trace
Program a 16 or 64-byte identifier to set and check the expected trace
Enable or disable the TIM (Trace Identifier Mismatch) alarm
Copy:
This function allows copying the received trace identifier from RX, making it easier on the user, specially for the longer strings, to minimize typos. It is also a quick
way to eliminate TIM alarms.
RX - JO [S]
UX400 10G e-Manual D07-00-058P RevA00
Page 184 of 209
Summary of Contents for UX400
Page 1: ...UX400 10G e Manual D07 00 058P RevA00 Page 1 of 209 ...
Page 33: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 33 of 209 ...
Page 37: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 37 of 209 ...
Page 142: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 142 of 209 ...
Page 189: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 189 of 209 ...
Page 205: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 205 of 209 ...