G1 byte (Path status)
High Order path status byte
Used to convey the path terminating status back to the originating path, thus allowing bidirectional monitoring of the complete path
Bits 1-4: Remote Error Indication (HP-REI) indicates number of bit errors detected by B3
Bit 5: Remote Defect indication (HP-RDI) set to 1 if signal failure is detected
Bits 6-7: Enhanced RDI information to differentiate between payload defects (HP-PLM), connectivity defects (HP-TIM, HP-UNQ) and server defects (HP-AIS,
LOP)
G1 Byte (HP Status)
F2 byte (HP user channel)
High Order Path user channel
VC-4 path user channel used for communication between path elements
H4 byte (TU Indicator)
Position or Sequence Indicator
Multiframe phase indicator used for tributary structured payloads
F3 byte (LP) user channel
Used for communication between path elements and is payload dependent.
K3 byte (HP APS)
Bits 1-4 are used for protection switching of VC-3 & 4 paths.
Bits 5-8 are a currently not used
N1 byte (HP)
UX400 10G e-Manual D07-00-058P RevA00
Page 177 of 209
Summary of Contents for UX400
Page 1: ...UX400 10G e Manual D07 00 058P RevA00 Page 1 of 209 ...
Page 33: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 33 of 209 ...
Page 37: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 37 of 209 ...
Page 142: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 142 of 209 ...
Page 189: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 189 of 209 ...
Page 205: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 205 of 209 ...