7.5.1.2 Path Overhead Layer
The following is a partial list of POH bytes and their corresponding functions:
J1 byte (STS Path Trace)
High Order VC-N path trace byte
A unique message is assigned to each path in a SDH network – therefore the path trace can be used to check continuity between any location on a
transmission path and the path source
This user programmable byte repeatedly transmits a 15-byte string plus 1 (CRC-7) byte so that a receiver can continually verify its connection with the
transmitter
A 64-byte free-format string is also permitted. It contains up to 62 characters plus carry return (CR) and line feed (LF), any unused characters are filled with
blanks (00h)
The message is transmitted one byte per VC-4 frame
J1 Byte (HP Path Trace)
B3 byte
Even code parity which determines if a transmission error has occurred over a path
Its value is calculated over all the bits of the previous VC-4
The computed checksum is placed in the B3 byte before scrambling
C2 byte (HP signal label) for SDH mode
Indicates mapping of the VC-n.
The table below indicates the standard C2 binary values:
C2 Byte (HP signal label)
UX400 10G e-Manual D07-00-058P RevA00
Page 176 of 209
Summary of Contents for UX400
Page 1: ...UX400 10G e Manual D07 00 058P RevA00 Page 1 of 209 ...
Page 33: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 33 of 209 ...
Page 37: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 37 of 209 ...
Page 142: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 142 of 209 ...
Page 189: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 189 of 209 ...
Page 205: ...Go back to top Go back to TOC UX400 10G e Manual D07 00 058P RevA00 Page 205 of 209 ...