D292106.8b.fm
Preparing to Run a Pre-programmed Job
Chapter 6: Operation
6- 11
3.
Press
Move To Pick
, then press
Pick Part.
Observe
the vacuum sensor which is located on top of the head
to see if it is set correctly for the current part. The
numbers should be lit in
green
with components on
the nozzle and
red
if components are not
Note:
See the
Chapter 6: Troubleshooting
for vac-
uum sensor adjustment procedures.
4.
Return to the
Head Setup Tab
. Press
Move To Place
, then press
Place Part.
5.
Check that the
Blow Off Pressure
is set correctly for the
current part.
The
Blow-off Pressure
Gauge
is located on
the front of the
Pick Head Bridge
. If components are not
dropping properly, loosen the locking nut and rotate to
adjust pressure levels. When the desired pressure level
is reached, tighten locking nut.
Setup Vision
The TM-403 Vision System will automatically revert to the previous inspection. If the
same part is being run, there is no need to retrain the camera. Proceed to Step 8. If a dif-
ferent job/inspection is being run, follow the setup instructions in
Chapter 4: Setup
.
Step 7:
Setup
Vision