3-10
TM-403 User’s Guide
Job Tab
D292106.6b.fm
3.
The third
Job Wizard
step sets up
Taper
operation.
A.
Tape Pitch
is determined by the carrier tape
selected. Use the
Pitch Setting Guide
on the taper to
determine the correct pitch. Press the
Tape Pitch
field to open a keypad and type in the desired value.
B. Seal
Type
toggles between
PSA
and
Heat
seal,
select correct seal type.
C.
The
Set Point
fields for the
Inner
and
Outer Sealer
are used to set the desired
temperature for Heat Seal. Enter the correct value in both fields, then press the
right
Arrow Key
to move to the next
Job Wizard
screen.
Note:
The TM-403 accommodates a wide range of carrier tapes and cover tapes. Set-
tings may vary from one tape product to another. The recommended starting point is 90°
C. The maximum recommended operating temperature is 160° C
.
The temperature for
each seal shoe should be increased or decreased as needed after running a peel force
test.
A
B
Job Wizard Step 3
C