4-24
TM-403 User’s Guide
Configure HMI Settings
D292106.7b.fm
a.
To manually set the
Place
Actuator
to
the correct nozzle height,
press
Place
Extend
b.
Use a 2.5mm hex wrench to hold the
Actuator Adjustment Screw
in place
from the bottom, while loosening the
Jam Nut
on top of the
Actuator
Adjustment Screw
with
an 8mm open
ended wrench
.
Lower the
Nozzle
until
the part is barely touching the top of
the pocket in the
Place Location
.
c.
Tighten the
Jam Nut
.
d.
Press
Place Retract
to retract the
Nozzle to a safe height.
e.
Press the right
Arrow Key
to move to
the next
Job Wizard
screen.
12.
Set Rotation Angle
a.
Press the Placement Rotation Angle field to toggle through the rotation
options. The options are 0, -90 and +90. Select the correct placement angle.
Step 6:
Setup HMI
NOZZLE
Summary of Contents for TM-403
Page 4: ......
Page 84: ...3 42 TM 403 User s Guide Run Tab D292106 6b fm...
Page 214: ...8 12 TM 403 User s Guide General Maintenance Tasks D292106 10a fm...
Page 220: ......