D292106.7b.fm
Configure HMI Settings
Chapter 4: Setup
4- 21
c.
Press
Rotate
to turn the nozzle so the set screw is accessible.
d.
Use a 2.5mm hex wrench to hold the
Actuator Adjustment Screw
in place from
the bottom, while loosening the
Jam Nut
on top of the
Actuator Adjustment Screw
with
an 8mm open ended wrench
.
Raise
the
Nozzle
until it is at a safe height so it
will not collide with the current part when
extended.
e.
Tighten the
Jam Nut
.
f.
Press the
Pick Extend
button
.
g.
Loosen the
Jam Nut
on top of the
Actuator Adjustment Screw
again, then
lower the
Nozzle
until it is barely touching the part in the
Pick Location
.
Note
: For all
Nozzle Tips
except the
Convum Tips
, the pick position should be set
just above the surface of the part with a very small clearance between the nozzle
and the part. Because the
Convum Nozzle Tips
are flexible, it is all right if the tip is
programmed to touch the part when picking.
h.
Tighten the
Jam Nut
.
i.
Press
Pick Retract
to retract the
Nozzle
to a safe height.
j.
Press
Rotate
to return the
Nozzle
to its original orientation.
k.
Use the
Index
arrow keys to move the pick head back to the Tray 1, Pocket 1
position.
l.
Press the right
Arrow
to move to the next
Job Wizard
screen.