background image

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (

lancerworldwide

.com) 

for immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access Contact Lancer Customer Service for assistance as required.

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit,  

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

IMPORTANT SAFETY INSTRUCTIONS

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

Lancer PN: 28-3040

 

Revision: 00-

0

 - 

April

 

2020

The dispenser is for indoor use only. This unit is not a toy. Children should be supervised not to play with appliance. It should not 

be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given  

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 65°F to 

105°F (18°C to 40°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained  

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

!

Intended Use

This system uses a flammable refrigerant under pressure. Do not tamper with it. Contact qualified service personal before disposal. 

In order to minimize the risk of possible ignition due to incorrect parts or improper service, only factory authorized personnel should 

perform service on the appliance and its component parts. Do not store explosive substances such as aerosol cans with a  

flammable propellant in this appliance. Replace component parts with like components. Only use genuine Lancer parts or parts 

certified by Lancer. Do not damage the refrigerant circuit.

Refrigerant Warning

CED-600 R-290 

LANCER INSTALLATION GUIDE

Warning; flammable material. Taking care to avoid causing a fire by igniting flammable material.

 

WARNING

®

9000

® 

Model 9000

Summary of Contents for 9000 series

Page 1: ...sion 00 0 April 2020 The dispenser is for indoor use only This unit is not a toy Children should be supervised not to play with appliance It should not be used by children or infirm persons without su...

Page 2: ...it Do not plug into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available Follow all local electrical codes when making connections Each disp...

Page 3: ...the counter top the dispenser base must be sealed to the counter top with a bead of clear silicone caulk or sealant which provides a smooth and easily cleanable bond to the counter 3 Once the dispens...

Page 4: ...cm could cause the lines to freeze ATTENTION The water bath compartment must be filled with water before plugging in the unit otherwise the compressor fan may not operate properly DO NOT use RO or pu...

Page 5: ...is present in regulator attachment nut ATTENTION Installing CO2 Supply 1 Connect high pressure CO2 regulator assembly to CO2 cylinder or bulk system Thread regulator nut on to tank then tighten nut wi...

Page 6: ...Plug the Pump Motor Connector back into the control box A Regulator Adjustment Screw B Adjust to 75 psi 0 517 MPa C Wrench A B C 9 Turn power on 10 Activate each valve until a steady flow of carbonate...

Page 7: ...of the first valve 2 Insert the programmer s 10 pin connector into the ID panel plug located on the front of the circuit board 3 When properly connected the programmer will run a self diagnostic test...

Page 8: ...amination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives or solvents on the dispen...

Page 9: ...t until there is no aftertaste Do not use a fresh water rinse This is a NSF requirement Residual sanitizing solution left in the system creates a health hazard CAUTION Cleaning and Sanitizing Nozzles...

Page 10: ...yrup flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 psi 0 550 MPa minimum 70 psi 0 480 MPa for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form uppe...

Page 11: ...3 Water flow rate too high 4 Nozzle and diffuser not installed 5 Nozzle and diffuser not clean 6 Air in BIB lines 7 Poor quality ice 8 High beverage temperature 1 Correct prior to dispenser Consider...

Page 12: ...ide com lancerworldwide com WIRING PLUMBING DIAGRAMS Plumbing Diagram PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S2 S1 S3 S4 S5 S6 PRESSURE SETTINGS CO 75 psi 50 psi WATER 2 PLA...