3-28
TM-401 User’s Guide
MTID Tab
D292104.6.fm
.
A.
Help Icon
B.
Head Jog Controls
C.
Pick Wizard Control buttons
A.
To see an illustration of the correct head placement, push the
Help
icon.
B.
The
Jog
buttons in the
Head Settings
section are used to jog the head forward or
backward along the X Axis (left/right) until the nozzle is centered over the last
Tube Pocket
.
Head Jog Step
is the distance in millimeters that the head will move when
Jog
is
pressed.
Note:
Enter
Jog Step
field values in the following format: XXX.XX. (i.e. 100.00).
The
Head Position
message indicates where the pick head is located in relation
to the
Home
position. The
Learned Position
indicates the current Pick position.
C.
Press the
Cancel
button to return to the
MTID Tab
. Once the
Learn
button has
been pressed, the
Cancel
button disappears.
Pressing
Learn
saves the current head position as the programmed pick location.
This is the position the pick head will move to along the X Axis (left/right) when
picking a part from the
Tube Feeder
.
Press the
Finish
button to calculate tube pitch and return to the
MTID Tab
.
Note:
The TM-401 will use these settings for the current job. To save
MTID Settings
for
future jobs, go to the
Job Tab,
select a job name and
Save
.
B
C
A
Summary of Contents for TM-401
Page 4: ......
Page 74: ...3 32 TM 401 User s Guide Run Tab D292104 6 fm ...
Page 146: ...5 44 TM 403 User s Guide Configure Inspection D292104 16 fm ...
Page 158: ...6 12 TM 401 User s Guide Preparing to Run a Pre programmed Job D292104 8a fm ...
Page 188: ...7 30 TM 401 User s Guide Adjusting PSA Seal Quality D292104 9a fm ...
Page 204: ...Appendix A Sensors A 6 SMC ZSE30 Vacuum Sensor D292104 11 fm ...
Page 208: ......
Page 284: ......
Page 286: ...Service and Parts Contacts 61053915 fm Page 2 ...
Page 288: ...TM 401 Document List D292104 15b fm Page 2 ...
Page 290: ......
Page 291: ......