3-24
TM-401 User’s Guide
Head Tab
D292104.6.fm
the pick head is homed, the current position will be 0.00. This distance is measured in mil-
limeters.
Press the right
Arrow
button to open the second
Head Setup
screen (shown below).
A.
The
Pick Extend/Pick Retract
button actuates the
pick solenoid
to enable the
operator to set the pick height.
The
Rotate Part
button rotates the
pick head
to the preset rotation angle.
The
Place Extend/Place Retract
button actuates the
place solenoid
to enable the
operator to set the place height.
B.
The
Part Placement Rotation Angle
is manually set during machine setup. The
options are 0, -90 and +90.
Head Screen 3
A
C
B
-90
0
+90
Rotation Options