7-24
TM-401 User’s Guide
Tips on Part Placement
D292104.9a.fm
3.
Press the
Right Arrow
to move to the next
Head Tab
..
Jog the head up or down until the nozzle is centered correctly over the place location.
When the nozzle is positioned correctly, press the
Set Place Position
button.
4.
Adjust
Place Position Z
. Manually adjust the right
Actuator Adjustment Screw
up or
down until the nozzle is extended the appropriate distance above the place location. You
may need to experiment with placing a part to determine what Z Axis height works best.
When the nozzle is positioned correctly, press the
Set Place Position
button.
Actuator
Adjustment
Screw